Phoenix atherectomy system

Rotational atherectomy system

ค้นหาผลิตภัณฑ์ที่คล้ายกัน

The Phoenix atherectomy system combines the benefits of existing atherectomy systems to deliver a unique atherectomy option to help physicians tailor the treatment approach for each patient.¹ It cuts, captures, and clears diseased tissue with one insertion. Phoenix treats a broad range of tissue types, from soft plaque to calcified arteries, and can be used for lesions above and below the knee.²,³

Features
Front cutter
Front cutter

Front cutter

Front cutter clears tissue in a way that may help reduce potential trauma to the vessel.³

Front cutter

Front cutter
Front cutter clears tissue in a way that may help reduce potential trauma to the vessel.³

Front cutter

Front cutter clears tissue in a way that may help reduce potential trauma to the vessel.³
Click here for more information
Front cutter
Front cutter

Front cutter

Front cutter clears tissue in a way that may help reduce potential trauma to the vessel.³
Capture and clearance
Capture and clearance

Capture and clearance

Continuous capture and passive clearance of debulked material into the catheter resulted in a <1% rate of symptomatic distal emboli in the EASE trial.⁴

Capture and clearance

Capture and clearance
Continuous capture and passive clearance of debulked material into the catheter resulted in a <1% rate of symptomatic distal emboli in the EASE trial.⁴

Capture and clearance

Continuous capture and passive clearance of debulked material into the catheter resulted in a <1% rate of symptomatic distal emboli in the EASE trial.⁴
Click here for more information
Capture and clearance
Capture and clearance

Capture and clearance

Continuous capture and passive clearance of debulked material into the catheter resulted in a <1% rate of symptomatic distal emboli in the EASE trial.⁴
Ease of use
Ease of use

Ease of use

Phoenix is battery-powered and handle-operated. No capital equipment or additional procedural accessories are required.

Ease of use

Ease of use
Phoenix is battery-powered and handle-operated. No capital equipment or additional procedural accessories are required.

Ease of use

Phoenix is battery-powered and handle-operated. No capital equipment or additional procedural accessories are required.
Click here for more information
Ease of use
Ease of use

Ease of use

Phoenix is battery-powered and handle-operated. No capital equipment or additional procedural accessories are required.
Deliverability
Deliverability

Deliverability

Low-profile, front-cutting design allows for direct lesion access without having to first pass a nosecone. The over-the-wire design aids in trackability and pushability of catheter.

Deliverability

Deliverability
Low-profile, front-cutting design allows for direct lesion access without having to first pass a nosecone. The over-the-wire design aids in trackability and pushability of catheter.

Deliverability

Low-profile, front-cutting design allows for direct lesion access without having to first pass a nosecone. The over-the-wire design aids in trackability and pushability of catheter.
Click here for more information
Deliverability
Deliverability

Deliverability

Low-profile, front-cutting design allows for direct lesion access without having to first pass a nosecone. The over-the-wire design aids in trackability and pushability of catheter.
Versatility
Versatility

Versatility

Offering of catheters has been shown to effectively treat most peripheral vasculature.⁴ • 1.5, 1.8 and 2.2mm tracking catheters are suited for treating small vessels or highly stenosed lesions. • 2.2 deflected catheter suited for more lumen gain in above and below the knee lesions.* • 2.4mm (deflecting) catheter is suited for larger vessels or eccentric lesions.³

Versatility

Versatility
Offering of catheters has been shown to effectively treat most peripheral vasculature.⁴ • 1.5, 1.8 and 2.2mm tracking catheters are suited for treating small vessels or highly stenosed lesions. • 2.2 deflected catheter suited for more lumen gain in above and below the knee lesions.* • 2.4mm (deflecting) catheter is suited for larger vessels or eccentric lesions.³

Versatility

Offering of catheters has been shown to effectively treat most peripheral vasculature.⁴ • 1.5, 1.8 and 2.2mm tracking catheters are suited for treating small vessels or highly stenosed lesions. • 2.2 deflected catheter suited for more lumen gain in above and below the knee lesions.* • 2.4mm (deflecting) catheter is suited for larger vessels or eccentric lesions.³
Click here for more information
Versatility
Versatility

Versatility

Offering of catheters has been shown to effectively treat most peripheral vasculature.⁴ • 1.5, 1.8 and 2.2mm tracking catheters are suited for treating small vessels or highly stenosed lesions. • 2.2 deflected catheter suited for more lumen gain in above and below the knee lesions.* • 2.4mm (deflecting) catheter is suited for larger vessels or eccentric lesions.³
  • Front cutter
  • Capture and clearance
  • Ease of use
  • Deliverability
See all features
Front cutter
Front cutter

Front cutter

Front cutter clears tissue in a way that may help reduce potential trauma to the vessel.³

Front cutter

Front cutter
Front cutter clears tissue in a way that may help reduce potential trauma to the vessel.³

Front cutter

Front cutter clears tissue in a way that may help reduce potential trauma to the vessel.³
Click here for more information
Front cutter
Front cutter

Front cutter

Front cutter clears tissue in a way that may help reduce potential trauma to the vessel.³
Capture and clearance
Capture and clearance

Capture and clearance

Continuous capture and passive clearance of debulked material into the catheter resulted in a <1% rate of symptomatic distal emboli in the EASE trial.⁴

Capture and clearance

Capture and clearance
Continuous capture and passive clearance of debulked material into the catheter resulted in a <1% rate of symptomatic distal emboli in the EASE trial.⁴

Capture and clearance

Continuous capture and passive clearance of debulked material into the catheter resulted in a <1% rate of symptomatic distal emboli in the EASE trial.⁴
Click here for more information
Capture and clearance
Capture and clearance

Capture and clearance

Continuous capture and passive clearance of debulked material into the catheter resulted in a <1% rate of symptomatic distal emboli in the EASE trial.⁴
Ease of use
Ease of use

Ease of use

Phoenix is battery-powered and handle-operated. No capital equipment or additional procedural accessories are required.

Ease of use

Ease of use
Phoenix is battery-powered and handle-operated. No capital equipment or additional procedural accessories are required.

Ease of use

Phoenix is battery-powered and handle-operated. No capital equipment or additional procedural accessories are required.
Click here for more information
Ease of use
Ease of use

Ease of use

Phoenix is battery-powered and handle-operated. No capital equipment or additional procedural accessories are required.
Deliverability
Deliverability

Deliverability

Low-profile, front-cutting design allows for direct lesion access without having to first pass a nosecone. The over-the-wire design aids in trackability and pushability of catheter.

Deliverability

Deliverability
Low-profile, front-cutting design allows for direct lesion access without having to first pass a nosecone. The over-the-wire design aids in trackability and pushability of catheter.

Deliverability

Low-profile, front-cutting design allows for direct lesion access without having to first pass a nosecone. The over-the-wire design aids in trackability and pushability of catheter.
Click here for more information
Deliverability
Deliverability

Deliverability

Low-profile, front-cutting design allows for direct lesion access without having to first pass a nosecone. The over-the-wire design aids in trackability and pushability of catheter.
Versatility
Versatility

Versatility

Offering of catheters has been shown to effectively treat most peripheral vasculature.⁴ • 1.5, 1.8 and 2.2mm tracking catheters are suited for treating small vessels or highly stenosed lesions. • 2.2 deflected catheter suited for more lumen gain in above and below the knee lesions.* • 2.4mm (deflecting) catheter is suited for larger vessels or eccentric lesions.³

Versatility

Versatility
Offering of catheters has been shown to effectively treat most peripheral vasculature.⁴ • 1.5, 1.8 and 2.2mm tracking catheters are suited for treating small vessels or highly stenosed lesions. • 2.2 deflected catheter suited for more lumen gain in above and below the knee lesions.* • 2.4mm (deflecting) catheter is suited for larger vessels or eccentric lesions.³

Versatility

Offering of catheters has been shown to effectively treat most peripheral vasculature.⁴ • 1.5, 1.8 and 2.2mm tracking catheters are suited for treating small vessels or highly stenosed lesions. • 2.2 deflected catheter suited for more lumen gain in above and below the knee lesions.* • 2.4mm (deflecting) catheter is suited for larger vessels or eccentric lesions.³
Click here for more information
Versatility
Versatility

Versatility

Offering of catheters has been shown to effectively treat most peripheral vasculature.⁴ • 1.5, 1.8 and 2.2mm tracking catheters are suited for treating small vessels or highly stenosed lesions. • 2.2 deflected catheter suited for more lumen gain in above and below the knee lesions.* • 2.4mm (deflecting) catheter is suited for larger vessels or eccentric lesions.³

ข้อกำหนดทางเทคนิค

1.8mm x 130cm tracking catheter
1.8mm x 130cm tracking catheter
Part Number
  • P18130K
Introducer size
  • 5F (greater than 1.8 mm)
Working length
  • 130 cm
Guidewire diameter
  • 0.014”
1.8mm x 149cm tracking catheter
1.8mm x 149cm tracking catheter
Part Number
  • P18149K
Introducer size
  • 5F (greater than 1.8 mm)
Working length
  • 149 cm
Guidewire diameter
  • 0.014”
2.2mm x 130cm tracking catheter
2.2mm x 130cm tracking catheter
Part Number
  • P22130K
Introducer size
  • 6F (greater than 2.2 mm)
Working length
  • 130 cm
Guidewire diameter
  • 0.014”
2.2mm x 149cm tracking catheter
2.2mm x 149cm tracking catheter
Part Number
  • P22149K
Introducer size
  • 6F (greater than 2.2 mm)
Working length
  • 149 cm
Guidewire diameter
  • 0.014”
2.4mm x 127cm deflecting catheter
2.4mm x 127cm deflecting catheter
Part Number
  • PD24127K
Introducer size
  • 7F (greater than 2.4 mm)
Working length
  • 127 cm
Guidewire diameter
  • 0.014”
Phoenix guidewire
Phoenix guidewire
Part Number
  • PG14300LF
Product
  • Phoenix guidewire
Length
  • 300 cm
Wire Support Level
  • Light
1.5mm x 149cm tracking catheter
1.5mm x 149cm tracking catheter
Part Number
  • P15149K
Working length
  • 149 cm
Introducer size
  • 4F (greater than 1.5mm)
Guidewire diameter
  • 0.014“
2.2mm x 130cm pre-deflected catheter
2.2mm x 130cm pre-deflected catheter
Part Number
  • PD22130K
Working length
  • 130 cm
Introducer size
  • 6F (greater than 2.2 mm)
Guidewire diameter
  • 0.014”
2.4mm x 130cm pre-deflected catheter
2.4mm x 130cm pre-deflected catheter
Part Number
  • PD24130K
Working length
  • 130 cm
Introducer size
  • 7F (greater than 2.4 mm)
Guidewire diameter
  • 0.014”
1.8mm x 130cm tracking catheter
1.8mm x 130cm tracking catheter
Part Number
  • P18130K
Introducer size
  • 5F (greater than 1.8 mm)
1.8mm x 149cm tracking catheter
1.8mm x 149cm tracking catheter
Part Number
  • P18149K
Introducer size
  • 5F (greater than 1.8 mm)
See all specifications
1.8mm x 130cm tracking catheter
1.8mm x 130cm tracking catheter
Part Number
  • P18130K
Introducer size
  • 5F (greater than 1.8 mm)
Working length
  • 130 cm
Guidewire diameter
  • 0.014”
1.8mm x 149cm tracking catheter
1.8mm x 149cm tracking catheter
Part Number
  • P18149K
Introducer size
  • 5F (greater than 1.8 mm)
Working length
  • 149 cm
Guidewire diameter
  • 0.014”
2.2mm x 130cm tracking catheter
2.2mm x 130cm tracking catheter
Part Number
  • P22130K
Introducer size
  • 6F (greater than 2.2 mm)
Working length
  • 130 cm
Guidewire diameter
  • 0.014”
2.2mm x 149cm tracking catheter
2.2mm x 149cm tracking catheter
Part Number
  • P22149K
Introducer size
  • 6F (greater than 2.2 mm)
Working length
  • 149 cm
Guidewire diameter
  • 0.014”
2.4mm x 127cm deflecting catheter
2.4mm x 127cm deflecting catheter
Part Number
  • PD24127K
Introducer size
  • 7F (greater than 2.4 mm)
Working length
  • 127 cm
Guidewire diameter
  • 0.014”
Phoenix guidewire
Phoenix guidewire
Part Number
  • PG14300LF
Product
  • Phoenix guidewire
Length
  • 300 cm
Wire Support Level
  • Light
1.5mm x 149cm tracking catheter
1.5mm x 149cm tracking catheter
Part Number
  • P15149K
Working length
  • 149 cm
Introducer size
  • 4F (greater than 1.5mm)
Guidewire diameter
  • 0.014“
2.2mm x 130cm pre-deflected catheter
2.2mm x 130cm pre-deflected catheter
Part Number
  • PD22130K
Working length
  • 130 cm
Introducer size
  • 6F (greater than 2.2 mm)
Guidewire diameter
  • 0.014”
2.4mm x 130cm pre-deflected catheter
2.4mm x 130cm pre-deflected catheter
Part Number
  • PD24130K
Working length
  • 130 cm
Introducer size
  • 7F (greater than 2.4 mm)
Guidewire diameter
  • 0.014”
  • 1. Rotational atherectomy refers to the Phoenix family of products. 2.4mm deflecting catheter and 2.2 mm auto-deflected catheter have directional cutting ability.
  • 2. Monitor flow of excised material into the disposal reservoir during operation of the Catheter. If flow of excised material ceases during the procedure, this is a sign that the Catheter drive system (cutter, torque shaft, or Handle motor drive) may not be operating properly.
  • 3. The Phoenix atherectomy 1.5 mm tracking catheter is indicated for vessels of 2.0 mm in diameter or above, the 1.8 mm tracking catheter is indicated for vessels 2.5 mm in diameter or above. The Phoenix 2.2 mm tracking and deflected as well as the 2.4 mm deflecting catheters are indicated for vessels of 3.0 mm in diameter or above. While the 1.5mm and 1.8 tracking as well as the 2.2 mm tracking and deflecting catheters are indicated for femoral, popliteal, or distal arteries located below the knee, the Phoenix 2.4 mm deflecting catheter is indicated for femoral and popliteal only. Refer to product IFU for detailed instructions. Warning: do not use the Phoenix atherectomy system in vessels smaller than the indicated size or harm to patient (vessel perforation, dissection or injury) could occur.
  • 4. Davis T, Ramaiah V, Niazi K, Martin Gissler H, Crabtree T. Safety and effectiveness of the Phoenix Atherectomy System in lower extremity arteries: Early and midterm outcomes from the prospective multicenter EASE study. Vascular. 2017 Dec;25(6):563-575. The Phoenix atherectomy 1.5 mm tracking and 2.2 mm deflecting catheter were not include in the EASE trial.
  • 5. Case study results are not predictive. Results in other cases may vary.
  • 6. Case performed by Dr. Joseph Griffin at Baton Rouge General Hospital.
  • 7. Center mass cutting device when the guidewire is centered.
  • 8. Case performed by Dr. William Crowder in Jackson, Mississippi.
  • 9. Case performed by Dr. Tom Davis in Detroit, MI.
  • Product availability is subject to country regulatory clearance. Please contact your local sales representative to check the availability in your country.
  • Phoenix atherectomy system is distributed by InterMed in New Zealand.
  • Always read the label and follow the directions for use.
  • Philips medical devices should only be used by physicians and teams trained in interventional techniques, including training in the use of this device.
  • Philips reserves the right to change product specifications without prior notification.

You are about to visit a Philips global content page

Continue

You are about to visit a Philips global content page

Continue

ไซต์ของเราสามารถดูได้ดีที่สุดด้วย Microsoft Edge, Google Chrome หรือ Firefox เวอร์ชันล่าสุด